Bathroom Zones For Fans
This is the area within a bath tub only 12v selv safety extra low voltage equipment can be used.
Bathroom zones for fans. In addition it is good practice to consider the area around a wash basin within a 60cm radius of any tap to be considered as zone 2. Vent axia recommends the use of ipx5 fans in the bathroom zone 1 and offers a range of ipx5 fans which also meets the regulations. Water and electricity make a potentially lethal combination. As you can see the illustrations show four distinct bathroom zones 0 1 2 and 3 referred to in the key as outside zones.
Recommended extractor fans which are rated to a minimum of ipx4 include. Zone 2 is an area stretching 0 6m outside the perimeter of the bath and to a height of 2 25m from the floor. 97m3 hr 26 l s noise. The interior of the bath or shower tray.
Zone 3 is anywhere outside zones 0 1 and 2 subject to specific limits and where no water jet is likely to be used. The exterior of the bath or shower tray to a height of 2 25 metres above the floor. 7 5w suitable for installation in all bathroom zones. Recommended by the efw team powerful silent bathroom extractor fan air extraction.
The extent of the zones in a bath or shower room can. Bathroom zone 1 ipx4. The area above the bath or shower tray area to a height of 2 25m from the finished floor level. Ipx4 or higher protection is required.
If there is no shower basin zone 2 is replaced by zone 1 extended to 1 2m around the fixed shower head. This is the zone beyond zones 0 and 1 continuing 0 6m horizontally and up to 2 25m vertically. In these bathroom zones an ip rating of at least ip44 is required. In this zone a minimum rating requirement is ipx4.
Wash basins are classified as being in zone 2. It is not recommended to install any ventilation product directly into this zone. 30 day money back guarantee save time check stock online and pick up in store. The three bathroom zones are.
Zone 2 for a shower room is the same height as zone 1 extended to 0 6m around the shower basin. If lighting is required in there any fitting used must use a low voltage supply that is a maximum of 12v and also be rated at least ipx7 which means it is totally immersion proof. Classification of zones zone 0. Zone 1 is the area above the bath or shower tray to a height of 2 25m from the floor.
Zone 0 is inside the bath or the shower tray itself. Bathroom zones electrical safety and using electrical equipment in bathrooms including lighting extractor fans shaver sockets and other electrical devices there are zones in your bathroom which reflect the increased danger to you from electrical appliances and electricity. As with zone 1 mains voltage items must be fitted to an rcd and low voltage items transformers must be installed outside of zone 2.